Quantitative micro-SPECT/CT for detecting focused ultrasound-induced blood-brain barrier opening in the rat.
Authors: Lin KJ, Liu HL, Hsu PH, Chung YH, Huang WC, Chen JC, Wey SP, Yen TC, Hsiao IT
Focused ultrasound has been discovered to be able to locally and reversibly increase the permeability of the blood-brain barrier (BBB). The purpose of this study was to investigate the feasibility of micro-single photon emission computed tomography/ computed tomography (micro-SPECT/CT) and 99mTc diethylenetriamine pentaacetate (99mTc-DTPA) for identifying disruption of the BBB induced by focused ultrasound in a rat model. We also assessed the amount of radiotracer that had crossed the BBB using various intensity levels of ultrasound energy. Immediately after sonication, three Sprague-Dawley rats were scanned for 2 h to determine the optimum time for data acquisition. Static SPECT with 1.5-h acquisition time was then performed in 12 rats sonicated with focused ultrasound pressure amplitudes of 0.78-2.45 MPa. Radiotracer and blue dye were used for lesion delineation. SPECT images were evaluated quantitatively and compared to results of histology and autoradiography. Terminal deoxynucleotidyl transferase biotin-desoxyuridine 5'-triphosphate (dUTP) nick end labeling staining was used to examine hemorrhage and tissue damage. The disruption to nondisruption radioactivity ratio showed a gradual increase from dynamic SPECT images, reaching a peak at 1.5 h post injection. The extent and intensity of radioactivity showed a good correlation with autoradiographic distribution and blue dye staining. SPECT measures correlated significantly with quantitative autoradiographic results (r(2)=0.90). According to SPECT findings, high acoustic powers allowed the delivery of larger amounts of radiotracer [0.001+/-0.002%ID (percent injected dose) under 0.78 MPa vs. 0.036+/-0.022%ID under 2.45 MPa]. Brain hemorrhage and tissue damage occurred at pressure amplitudes higher than 1.9 MPa. Our data demonstrate the usefulness of (99m)Tc-DTPA micro-SPECT/CT for detecting focused ultrasound-induced BBB disruption in the rat. This method may be used in vivo in combination with quantitative analysis for evaluating the amount of BBB opening.
Introduction
Purpose
Drug delivery with BBB opening
Study Objective
To evaluate whether quantitative micro-SPECT/CT can detect focused ultrasound-induced blood–brain barrier opening in rats.
Animal model / Human subject
Rat (Sprague-Dawley); strain not specified; age not specified; sex male
Disease model
Healthy
Targeted brain region(s)
Striatum
Cargo name and characteristics
99mTc-DTPA
Route of administration
Intravenous
Outcomes and Safety
Summary of Outcomes
FUS induced transient BBBO in rats, quantitatively detected by micro-SPECT/CT, with 99mTc-DTPA uptake increasing with higher acoustic pressure
Duration of biological effect
1.5 h
Safety-related matter
No tissue damage < 1.1 Mpa, occasional erythrocyte extravasation at 2.45 Mpa, hemorrhage and apoptosis occurred at >= 3.48 Mpa
Brain Region
Ultrasound Parameters
Ultrasound instrument
Focused ultrasound transducer (Imasonic, Besancon, France)
FUS Frequency
1.5 MHz
FUS Pressure
0.78-2.45 Mpa
FUS Mode
pulsed
Pulse duration
10 ms
Duration of a single FUS session
30 s
Focal Characteristics
Focal depth: None; Focal length: 80 mm; Aperture size: 60 mm
Treatment frequency
Single