Kranion, an open-source environment for planning transcranial focused ultrasound surgery: technical note.

Authors: Sammartino F, Beam DW, Snell J, Krishna V

Transcranial focused ultrasound (FUS) ablation is an emerging incision-less treatment for neurological disorders. The factors affecting FUS treatment efficiency are not well understood. Kranion is open-source software that allows the user to simulate the planning stages of FUS treatment and to "replay" previous treatments for off-line analysis. This study aimed to investigate the relationship between skull parameters and treatment efficiency and to create a metric to estimate temperature rise during FUS. CT images from 28 patients were analyzed to validate the use of Kranion. For stereotactic targets within each patient, individual transducer element incident angles, skull density ratio, and skull thickness measurements were recorded. A penetration metric (the "beam index") was calculated by combining the energy loss from incident angles and the skull thickness. Kranion accurately estimated the patient's skull and treatment parameters. The authors observed significant changes in incident angles with different targets in the brain. Using the beam index as a predictor of temperature rise in a linear-mixed-effects model, they were able to predict the average temperature rise at the focal point during ablation with < 21% error (55°C ± 3.8°C) in 75% of sonications, and with < 44% (55°C ± 7.9°C) in 97% of sonications. This research suggests that the beam index can improve the prediction of temperature rise during FUS. Additional work is required to study the relationship between temperature rise and lesion shape and clinical outcomes.

Introduction

Purpose thermal ablation
Study Objective Develop and validate Kranion, an open-source software for planning transcranial focused ultrasound surgery, and create a beam index metric to predict temperature rise during ablation
Animal model / Human subject human (essential tremor or Parkinson's disease patients)
Disease model essential tremor, Parkinson's disease
MRI or image guidance method Yes (CT and MRI)
Targeted brain region(s) Nucleus accumbens

Outcomes and Safety

Summary of Outcomes Kranion software accurately estimated skull parameters (SDR) and active/effective elements compared to vendor values. The beam index (integrating incident angle and skull thickness) predicted average temperature rise at the focal point with <21% error (55°C±3.8°C) in 75% of sonications and <44% error (55°C±7.9°C) in 97% of sonications, using a linear mixed-effects model with energy and beam index as covariates.

Brain Region

Ultrasound Parameters

Ultrasound instrument ExAblate (InSightec)
Treatment frequency single session (multiple sonications per patient)