Pitt Shield

Pulse sequence and timing of contrast-enhanced MRI for assessing blood-brain barrier disruption after transcranial focused ultrasound in the presence of hemorrhage.

Authors: Weng JC, Wu SK, Yang FY, Lin WL, Tseng WY

To optimize the timing of contrast-enhanced magnetic resonance imaging (MRI) that best indicates blood-brain barrier (BBB) disruption induced by focused ultrasound (FUS) along with an ultrasound contrast agent (UCA) and to verify that the contrast-enhanced spin-echo MRI sequence can indicate the degree and location of BBB disruption in the presence of hemorrhage better than a gradient-echo sequence. Sonication was applied to 12 rat brains with four different doses of UCA to cause variable degrees of hemorrhage. Two imaging sequences were performed to acquire T1-weighted (T1W) images at two time-points after the administration of a T1-shortening contrast agent. The contrast enhancement at the sonicated regions was quantified and correlated against Evans blue (EB) staining. The spin-echo T1W images at 10 minutes post-contrast enhancement showed the best correlation with EB staining in both quantity of EB extravasation (r = 0.812; P < 0.01) and spatial distribution (r = 0.528, P < 0.01). This capability was more robust than the gradient-echo sequence. Our results suggest that contrast-enhanced T1W spin-echo sequence acquired in the early phase post-contrast enhancement should be considered to monitor the degree and location of BBB disruption under the possibility of hemorrhage induced by FUS.

Introduction

Purpose Drug delivery with BBB opening
Study Objective Determine the optimal contrast-enhanced MRI pulse sequence and timing to assess blood–brain barrier disruption after transcranial focused ultrasound in the presence of hemorrhage.
Animal model / Human subject Rat
Disease model Hemorrhage
MRI or image guidance method MRI (contrast-enhanced T1-weighted spin-echo and gradient-echo sequences)

Outcomes and Safety

Summary of Outcomes MRI pulse sequence and post-contrast timing affect evaluation of FUS-induced BBB disruption with hemorrhage. Spin-echo T1W imaging at 10 minutes post-contrast correlates best with Evans blue staining.
Safety-related matter The provided text contains only the manuscript title and includes no mention of safety findings or adverse effects.

Brain Region

Visualization unavailable

Ultrasound Parameters

Focal Characteristics Focal depth: None; Focal length: None; Aperture size: None

We are open to feedback. If you see a mistake or have a suggestion, please contact us.

← Back to Search