Detecting blood-brain barrier disruption within minimal hemorrhage following transcranial focused ultrasound: a correlation study with contrast-enhanced MRI.
Authors: Weng JC, Wu SK, Lin WL, Tseng WY
Focused ultrasound combined with an intravascular ultrasound contrast agent can induce transient disruption of the blood-brain barrier, and the blood-brain barrier disruption can be detected by contrast-enhanced MRI. There is, however, no study investigating the ability of various MR methods to detect focused ultrasound-induced blood-brain barrier disruption within minimal hemorrhage. Sonication was applied to 15 rat brains with four different doses of ultrasound contrast agent (0, 10, 30, or 50 μL/kg), and contrast-enhanced T1-weighted spin echo, gradient echo images, and longitudinal relaxation rate mapping along with effective transverse relaxation time-weighted and susceptibility-weighted images were acquired. Volume-of-interest-based and threshold-based analyses were performed to quantify the contrast enhancement, which was then correlated with the ultrasound contrast agent dose and with the amount of Evans blue extravasation. Both effective transverse relaxation time-weighted and susceptibility-weighted images did not detect histology-proved intracranial hemorrhage at 10 μL/kg, but MRI failed to detect mild intracranial hemorrhage at 30 μL/kg. All tested sequences showed detectable contrast enhancement increasing with ultrasound contrast agent dose. In correlating with Evans blue extravasation, the gradient echo sequence was slightly better than the spin echo sequence and was comparable to longitudinal relaxation rate mapping. In conclusion, both gradient echo and spin echo sequences were all reliable in indicating the degree of focused ultrasound-induced blood-brain barrier disruption within minimal hemorrhage.
Introduction
Purpose
Drug delivery with BBB opening
Study Objective
To determine whether blood-brain barrier disruption within minimal hemorrhage after transcranial focused ultrasound can be detected and correlated with contrast-enhanced MRI.
Disease model
Blood-brain barrier disruption with minimal hemorrhage following transcranial focused ultrasound
Cargo name and characteristics
Gadolinium-based MRI contrast agent (small-molecule contrast agent)
Outcomes and Safety
Summary of Outcomes
Transcranial focused ultrasound produced blood–brain barrier disruption accompanied by minimal hemorrhage, which was reliably detected and correlated using contrast-enhanced MRI; no specific focused ultrasound parameter settings are reported in the provided text.
Safety-related matter
The provided text (title only) contains no explicit mention of safety outcomes or adverse effects; it only refers to blood-brain barrier disruption and minimal hemorrhage following transcranial focused ultrasound.
Brain Region
Ultrasound Parameters
Focal Characteristics
Focal depth: None; Focal length: None; Aperture size: None
We are open to feedback. If you see a mistake or have a suggestion, please contact us.