Acoustic cavitation-based monitoring of the reversibility and permeability of ultrasound-induced blood-brain barrier opening.
Authors: Sun T, Samiotaki G, Wang S, Acosta C, Chen CC, Konofagou EE
Cavitation events seeded by microbubbles have been previously reported to be associated with MR- or fluorescent-contrast enhancement after focused ultrasound (FUS)-induced blood-brain barrier (BBB) opening. However, it is still unknown whether bubble activity can be correlated with the reversibility (the duration of opening and the likelihood of safe reinstatement) and the permeability of opened BBB, which is critical for the clinical translation of using passive cavitation detection to monitor, predict and control the opening. In this study, the dependence of acoustic cavitation on the BBB opening duration, permeability coefficient and histological damage occurrence were thus investigated. Transcranial pulsed FUS at 1.5 MHz in the presence of systemically circulating microbubbles was applied in the mouse hippocampi (n = 60). The stable and inertial cavitation activities were monitored during sonication. Contrast-enhanced MRI was performed immediately after sonication and every 24 h up to 6 d thereafter, to assess BBB opening, brain tissue permeability and potential edema. Histological evaluations were used to assess the occurrence of neurovascular damages. It was found that stable cavitation was well correlated with: (1) the duration of the BBB opening (r(2) = 0.77); (2) the permeability of the opened BBB (r(2) = 0.82); (3) the likelihood of safe opening (P < 0.05, safe opening compared to cases of damage; P < 0.0001, no opening compared to safe opening). The inertial cavitation dose was correlated with the resulting BBB permeability (r(2) = 0.72). Stable cavitation was found to be more reliable than inertial cavitation at assessing the BBB opening within the pressure range used in this study. This study demonstrates that the stable cavitation response during BBB opening holds promise for predicting and controlling the restoration and pharmacokinetics of FUS-opened BBB. The stable cavitation response therefore showed great promise in predicting the BBB opening duration, enabling thus control of opening according to the drug circulation time. In addition, avoiding adverse effects in the brain and assessing the pharmacokinetics of the compounds delivered can also be achieved by monitoring and controlling the stable cavitation emissions.
Introduction
Purpose
Drug delivery with BBB opening
Study Objective
To determine whether stable and inertial cavitation measured during focused ultrasound-induced blood-brain barrier opening can predict the opening duration, permeability, and likelihood of histological damage in mice.
Animal model / Human subject
Mouse (Mus musculus); strain None; age None; sex None
Disease model
Focused ultrasound-induced blood-brain barrier (BBB) opening in mouse hippocampus
Targeted brain region(s)
Hippocampi
Outcomes and Safety
Summary of Outcomes
Transcranial pulsed FUS (1.5 MHz) with circulating microbubbles opened the mouse hippocampal BBB and stable cavitation emissions reliably predicted opening duration, permeability and safe/reversible opening (r2≈0.77–0.82; P<0.05), whereas inertial cavitation only correlated with permeability (r2≈0.72) and was less reliable — thus stable cavitation monitoring was the successful parameter for predicting and controlling FUS-induced BBB opening.
Safety-related matter
The study assessed potential neurovascular damage and edema and reported that stable cavitation activity was strongly correlated with a higher likelihood of safe BBB opening compared with cases showing damage (P < 0.05), while inertial cavitation dose correlated with BBB permeability. The authors conclude that monitoring and controlling stable cavitation emissions can help avoid adverse effects in the brain.
Brain Region
Ultrasound Parameters
FUS Frequency
1.5 MHz
FUS Mode
pulsed
Focal Characteristics
Focal depth: None; Focal length: None; Aperture size: None
Treatment frequency
Single