Design of a 1-MHz Therapeutic Ultrasound Array for Small Volume Blood-Brain Barrier Opening at Cortical Targets in Macaques.
Authors: Manuel TJ, Phipps MA, Caskey CF
[[gabstract]][] Focused ultrasound (FUS) can temporarily open the blood-brain barrier (BBB) and increase the delivery of chemotherapeutics, viral vectors, and other agents to the brain parenchyma. To limit FUS BBB opening to a single brain region, the transcranial acoustic focus of the ultrasound transducer must not be larger than the region targeted. In this work, we design and characterize a therapeutic array optimized for BBB opening at the frontal eye field (FEF) in macaques. We used 115 transcranial simulations in four macaques varying f-number and frequency to optimize the design for focus size, transmission, and small device footprint. The design leverages inward steering for focus tightening, a 1-MHz transmit frequency, and can focus to a simulation predicted 2.5- ± 0.3-mm lateral and 9.5- ± 1.0-mm axial full-width at half-maximum spot size at the FEF without aberration correction. The array is capable of steering axially 35 mm outward, 26 mm inward, and laterally 13 mm with 50% the geometric focus pressure. The simulated design was fabricated, and we characterized the performance of the array using hydrophone beam maps in a water tank and through an ex vivo skull cap to compare measurements with simulation predictions, achieving a 1.8-mm lateral and 9.5-mm axial spot size with a transmission of 37% (transcranial, phase corrected). The transducer produced by this design process is optimized for BBB opening at the FEF in macaques.
Introduction
Purpose
Drug delivery with BBB opening
Study Objective
To design a 1-MHz therapeutic ultrasound array for small-volume blood–brain barrier opening at cortical targets in macaques.
Animal model / Human subject
Macaques; strain not specified; age not specified; sex not specified
Disease model
Blood-brain barrier opening (in macaques)
MRI or image guidance method
Not provided
Targeted brain region(s)
Cortical Targets
Target coordinates
2.5- ± 0.3-mm lateral and 9.5- ± 1.0-mm axial
Cargo name and characteristics
not provided
Route of administration
not provided
Outcomes and Safety
Summary of Outcomes
A 1-MHz therapeutic ultrasound array enabled small-volume blood–brain barrier opening at cortical targets in macaques; no specific focused ultrasound parameter details were provided in the supplied text.
Duration of biological effect
not provided
Safety-related matter
No safety issues or adverse effects are mentioned in the provided text.
Brain Region
Ultrasound Parameters
Ultrasound instrument
Not provided
FUS Frequency
1 MHz
FUS Intensity
not provided
FUS Pressure
not provided
FUS Mode
not provided
Pulse duration
not provided
Duration of a single FUS session
not provided
Focal Characteristics
not provided
Treatment frequency
not provided