Pitt Shield

Amyloid β Plaque Reduction With Antibodies Crossing the Blood-Brain Barrier, Which Was Opened in 3 Sessions of Focused Ultrasound in a Rabbit Model.

Authors: Alecou T, Giannakou M, Damianou C

The main objective of this study was to remove amyloid β plaques by applying multiple sessions of focused ultrasound (US)-induced blood-brain barrier (BBB) opening using microbubbles with and without delivery of antibodies in a rabbit model. The animal model was achieved by feeding a high-cholesterol diet to rabbits for 4 months. Fifty-two New Zealand White rabbits were divided into treatment groups: untreated control, high-cholesterol diet only, antibodies only, focused US only, and focused US and antibodies. Three sessions of focused US were administered to the treatment groups. It was shown that with this animal model, the plaques were 30 μm in diameter. By increasing the number of sessions, the number of plaques decreased (both for focused US only and focused US and antibodies). Without the application of focused US, the average number of plaques dropped from 200/cm<sup>2</sup> (before treatment) to 170/cm<sup>2</sup> (after treatment). The effect of treatment with focused US with antibodies was more drastic. With 3 BBB opening sessions, the average number of plaques was reduced from 200 to 78/cm<sup>2</sup> . This feasibility study had demonstrated that by opening the BBB, it will be possible to deliver exogenous antibodies to the brain, thus eliminating amyloid β plaques. More importantly with repeated opening of the BBB (3 times in this study), the reduction in the number of plaques was increased.

Introduction

Purpose Drug delivery with BBB opening
Study Objective To determine whether opening the blood-brain barrier with three sessions of focused ultrasound enables antibody delivery that reduces amyloid β plaques in a rabbit model.
Animal model / Human subject Rabbit (Oryctolagus cuniculus), strain None, age None, sex None
Disease model Alzheimer's disease
Cargo name and characteristics Anti-amyloid-β antibodies (protein)

Outcomes and Safety

Summary of Outcomes Three sessions of focused ultrasound opened the blood–brain barrier in rabbits, enabling antibody delivery and producing a reduction in amyloid-β plaque burden; no specific focused ultrasound parameter variations or multiple tested settings were reported.
Safety-related matter The provided text (title only) contains no mention of safety findings or adverse effects.

Brain Region

Visualization unavailable

Ultrasound Parameters

Focal Characteristics Focal depth: None; Focal length: None; Aperture size: None
Treatment frequency multiple sessions

We are open to feedback. If you see a mistake or have a suggestion, please contact us.

← Back to Search