Investigation of the Safety of Focused Ultrasound-Induced Blood-Brain Barrier Opening in a Natural Canine Model of Aging.
Authors: O'Reilly MA, Jones RM, Barrett E, Schwab A, Head E, Hynynen K
<b>Rationale:</b> Ultrasound-mediated opening of the Blood-Brain Barrier(BBB) has shown exciting potential for the treatment of Alzheimer's disease(AD). Studies in transgenic mouse models have shown that this approach can reduce plaque pathology and improve spatial memory. Before clinical translation can occur the safety of the method needs to be tested in a larger brain that allows lower frequencies be used to treat larger tissue volumes, simulating clinical situations. Here we investigate the safety of opening the BBB in half of the brain in a large aged animal model with naturally occurring amyloid deposits. <b>Methods:</b> Aged dogs naturally accumulate plaques and show associated cognitive declines. Low-frequency ultrasound was used to open the BBB unilaterally in aged beagles (9-11yrs, n=10) in accordance with institutionally approved protocols. Animals received either a single treatment or four weekly treatments. Magnetic resonance imaging(MRI) was used to guide the treatments and assess the tissue effects. The animals underwent neurological testing during treatment follow-up, and a follow-up MRI exam 1 week following the final treatment. <b>Results:</b> The permeability of the BBB was successfully increased in all animals (mean enhancement: 19±11% relative to untreated hemisphere). There was a single adverse event in the chronic treatment group that resolved within 24 hrs. Follow-up MRI showed the BBB to be intact with no evidence of tissue damage in all animals. Histological analysis showed comparable levels of microhemorrhage between the treated and control hemispheres in the prefrontal cortex (single/repeat treatment: 1.0±1.4 vs 0.4±0.5/5.2±1.8 vs. 4.0±2.0). No significant differences were observed in beta-amyloid load (single/repeat: p=0.31/p=0.98) although 3/5 animals in each group showed lower Aβ loads in the treated hemisphere. <b>Conclusion:</b> Whole-hemisphere opening of the BBB was well tolerated in the aged large animal brain. The treatment volumes and frequencies used are clinically relevant and indicate safety for clinical translation. Further study is warranted to determine if FUS has positive effects on naturally occurring amyloid pathology.
Introduction
Purpose
Drug delivery with BBB opening
Study Objective
To assess the safety of unilateral low-frequency ultrasound-mediated blood–brain barrier opening, using single and repeated treatments, in aged beagles with naturally occurring amyloid pathology.
Animal model / Human subject
Dog (Canis lupus familiaris), beagle, 9–11 years old, sex not specified
Disease model
Alzheimer's disease
MRI or image guidance method
Magnetic resonance imaging (MRI) guidance
Targeted brain region(s)
Unilateral Whole Hemisphere (Half Of The Brain)
Outcomes and Safety
Summary of Outcomes
Low‑frequency transcranial focused ultrasound (FUS) reliably and transiently increased BBB permeability (mean enhancement 19±11%) in aged beagles with no MRI- or histology-detected brain tissue damage and only comparable levels of microhemorrhage to controls; there was no statistically significant group‑level reduction in Aβ though 3/5 animals per group showed lower Aβ in the treated hemisphere and one reversible adverse event occurred. Successful parameters included whole‑hemisphere low‑frequency FUS delivered with a single‑element focused transducer in both single and repeated (four weekly) treatment paradigms, using multiple intravenous microbubble injections (up to 13 injections per treatment at ~0.2 ml/kg per injection).
Duration of biological effect
24 hours
Safety-related matter
One minor adverse event (bloody urine and vomiting) occurred in a chronically treated animal and resolved within 24 hours after IV fluids and antibiotics; a separate technical error caused thermal damage to overlying muscle in the first animal but produced no observable brain injury. Otherwise MRI, histology, and neurological testing showed no brain tissue damage or functional deficits and microhemorrhage counts were comparable between treated and control hemispheres, indicating whole-hemisphere BBB opening was well tolerated.
Brain Region
Ultrasound Parameters
Focal Characteristics
Focal depth: None; Focal length: None; Aperture size: None
Treatment frequency
Both single and multiple sessions