Pitt Shield

Speed of Sound and Attenuation Temperature Dependence of Bovine Brain: Ex Vivo Study.

Authors: Dahis D, Azhari H

Brain treatments using focused ultrasound (FUS) offer a new range of noninvasive transcranial therapies. The acoustic energy deposition during these procedures may induce a temperature elevation in the tissue; therefore, noninvasive thermal monitoring is essential. Magnetic resonance imaging is the current adopted monitoring modality, but its high operational costs and limited availability may hinder the accessibility to FUS treatments. Aiming at the development of a thermometric ultrasound (US) method for the brain, the specific objective of this investigation was to study the acoustic thermal response of the speed of sound (SOS) and attenuation coefficient (AC) of different brain tissues: namely white matter (WM) and cortical matter. Sixteen ex vivo bovine brain samples were investigated. These included 7 WM and 9 cortical matter samples. The samples were gradually heated to about 45°C and then repeatedly scanned while cooling using a computerized US system in the through-transmission mode. The temperature was simultaneously registered with thermocouples. From the scans, the normalized SOS and AC for both tissues were calculated. The results demonstrated a characteristic cooldown temporal behavior for the normalized AC and SOS curves, which were related to the temperature. The SOS curves enabled clear differentiation between the tissue types but depicted more scattered trajectories for the WM tissue. As for the AC curves, the WM depicted a linear behavior in relation to the temperature. However, both tissue types had rather similar temperature patterns. These findings may contribute to the development of a US temperature-monitoring method during FUS procedures.

Introduction

Purpose Thermal ablation
Study Objective To characterize how the speed of sound and acoustic attenuation in ex vivo bovine brain tissue vary with temperature.
Animal model / Human subject Bovine (cow, Bos taurus); strain None; age None; sex None
Disease model Healthy

Outcomes and Safety

Summary of Outcomes The study characterized temperature-dependent changes in acoustic properties of ex vivo bovine brain, specifically measuring how speed of sound and attenuation vary with temperature; no focused ultrasound stimulation parameters were tested or reported.
Safety-related matter No safety concerns or adverse effects are mentioned in the provided text; only the paper title was supplied, so no safety-related information is reported.

Brain Region

Visualization unavailable

Ultrasound Parameters

Focal Characteristics Focal depth: None; Focal length: None; Aperture size: None

We are open to feedback. If you see a mistake or have a suggestion, please contact us.

← Back to Search