Pitt Shield

A Magnetic Resonance-Guided Focused Ultrasound Neuromodulation System With a Whole Brain Coil Array for Nonhuman Primates at 3 T.

Authors: Li Y, Lee J, Long X, Qiao Y, Ma T, He Q, Cao P, Zhang X, Zheng H

The phased-array radio frequency (RF) coil plays a vital role in magnetic resonance-guided focused ultrasound (MRgFUS) neuromodulation studies, where accurate brain functional stimulations and neural circuit observations are required. Although various designs of phased-array coils have been reported, few are suitable for ultrasound stimulations. In this study, an MRgFUS neuromodulation system comprised of a whole brain coverage non-human primate (NHP) RF coil and an MRI-compatible ultrasound device was developed. When compared to a single loop coil, the NHP coil provided up to a 50% increase in the signal-to-noise ratio (SNR) in the brain and acquired better anatomical image-quality. The NHP coil also demonstrated the ability to achieve higher spatial resolution and reduce distortion in echo-planer imaging (EPI). Ultrasound beam characteristics and transcranial magnetic resonance acoustic radiation force (MR-ARF) were measured for simulated positions, and calculated B<sub>0</sub> maps were employed to establish MRI-compatibility. The differences between focused off and on ultrasound techniques were measured using SNR, g-factors, and temporal SNR (tSNR) analyses and all deviations were under 2.3%. The EPI images quality and stable tSNR demonstrated the suitability of the MRgFUS neuromodulation system to conduct functional MRI studies. Last, the time course of the blood oxygen level dependent (BOLD) signal of posterior cingulate cortex in a focused ultrasound neuromodulation study was detected and repeated with MR thermometry.

Introduction

Purpose Transcranial ultrasound stimulation
Study Objective To develop and evaluate an MR-guided focused ultrasound neuromodulation system with a whole-brain coil array for nonhuman primates at 3 T.
Animal model / Human subject Nonhuman primates (species None; strain None; age None; sex None)
Disease model Healthy
MRI or image guidance method Magnetic resonance imaging (MRI) guidance

Outcomes and Safety

Summary of Outcomes No biological or behavioral effects are reported in the provided excerpt; the paper appears to describe development of an MR-guided focused ultrasound neuromodulation system with a whole-brain coil array for nonhuman primates at 3 T, and no focused ultrasound parameters or efficacy results are given in the available text.
Safety-related matter No safety-related information or adverse effects are mentioned in the provided text.

Brain Region

Visualization unavailable

Ultrasound Parameters

Focal Characteristics Focal depth: None; Focal length: None; Aperture size: None

We are open to feedback. If you see a mistake or have a suggestion, please contact us.

← Back to Search