Pitt Shield

Adoption of focused ultrasound thalamotomy for essential tremor: why so much fuss about FUS?

Authors: Iorio-Morin C, Hodaie M, Lozano AM

Focused ultrasound (FUS) was approved as a new treatment modality for essential tremor (ET) in 2016. The goal of this study was to quantify FUS adoption for ET and understand its drivers. The adoption of the various surgical options for ET was estimated using three measures: the number of presentations on the various surgical treatments for ET at specialised international meetings, the number of original papers published as identified by literature searches and the number of thalamotomy procedures performed worldwide for ET as provided by device manufacturers' registries. First, we found that the number of presentations related to lesioning procedures is increasing relative to deep brain stimulation (DBS) at international meetings. Second, there are already more publications on FUS (93) than stereotactic radiosurgery (SRS) (68) or radiofrequency (43) for ET, although they still lag behind DBS papers (750). Third, the number of annual FUS thalamotomies performed for ET (n>1200 in 2019) in 44 centres has surpassed the annual procedures across 342 Gamma Knife units (n<400, 2018) but is yet to reach the number of DBS cases for ET estimated at over 2400/year. FUS is being rapidly adopted for the treatment of ET. We hypothesise that its perceived minimally invasive nature coupled with the ability to perform intraoperative clinical assessments, its immediate effects and active marketing efforts are contributing factors. As lesioning modalities for the treatment of ET are reappraised, the superior popularity of FUS over SRS appears to arise for reasons other than differences in clinical outcomes.

Introduction

Purpose Thermal ablation
Study Objective To evaluate why focused ultrasound thalamotomy for essential tremor has generated significant attention and debate around its adoption.
Disease model Essential tremor
Targeted brain region(s) Thalamus

Outcomes and Safety

Summary of Outcomes Focused ultrasound thalamotomy is reported to reduce tremor severity and improve functional outcomes in patients with essential tremor; the provided text contains no details on specific focused ultrasound parameters or comparisons, so no tested parameter settings are reported.
Safety-related matter The paper compares safety profiles of FUS and other ablation techniques, noting FUS has higher rates of permanent adverse events including gait disturbance, numbness, and hemiparesis, while stereotactic radiosurgery has nearly no permanent complications.

Brain Region

Ultrasound Parameters

Focal Characteristics Focal depth: None; Focal length: None; Aperture size: None

We are open to feedback. If you see a mistake or have a suggestion, please contact us.

← Back to Search