A pilot clinical study of low-intensity transcranial focused ultrasound in Alzheimer's disease.

Authors: Jeong H, Im JJ, Park JS, Na SH, Lee W, Yoo SS, Song IU, Chung YA

Increasing attention has been paid to low-intensity transcranial focused ultrasound (tFUS) for its potential therapeutic effects in Alzheimer's disease (AD). While preclinical studies have shown promising therapeutic effects of low-intensity tFUS in AD models, its efficacy and safety remain unclear in humans. In this pilot study, we investigated the effects of low-intensity tFUS on blood-brain barrier opening, the regional cerebral metabolic rate of glucose (rCMRglu), and cognition in patients with AD. After receiving institutional review board approval, four patients with AD received tFUS to the hippocampus immediately after an intravenous injection of a microbubble ultrasound contrast agent. Sonication was delivered at low-intensity, at a pressure level below the threshold for blood-brain barrier opening. Patients underwent brain magnetic resonance imaging, 18F-fluoro-2-deoxyglucose positron emission tomography, and neuropsychological assessments before and after the tFUS procedure. A whole-brain voxel-wise paired t test was conducted to compare rCMRglu before and after tFUS. The sonication, as anticipated, did not show evidence of active blood-brain barrier opening on T1 dynamic contrast-enhanced magnetic resonance imaging. rCMRglu in the superior frontal gyrus (P<0.001), middle cingulate gyrus (P<0.001), and fusiform gyrus increased after tFUS (P=0.001). Patients demonstrated mild improvement in measures of memory, executive, and global cognitive function following tFUS. No adverse events were reported. These results suggest that hippocampal sonication with low-intensity tFUS may have beneficial effects on cerebral glucose metabolism and cognitive function in patients with AD. Further larger studies are needed to confirm the therapeutic efficacy of tFUS in AD.

Introduction

Purpose Transcranial ultrasound stimulation
Study Objective To evaluate the safety and effects of low-intensity transcranial focused ultrasound targeted to the hippocampus on blood–brain barrier opening, regional cerebral glucose metabolism, and cognition in patients with Alzheimer's disease.
Animal model / Human subject Human (Homo sapiens), strain: N/A, age: None, sex: None
Disease model Alzheimer's disease
Targeted brain region(s) Hippocampus

Outcomes and Safety

Summary of Outcomes Low-intensity hippocampal tFUS (in situ pressure ~135 kPa, MI 0.27) increased regional cerebral glucose metabolism in the right superior frontal gyrus, right middle cingulate gyrus, and left fusiform gyrus and produced mild improvements in memory, executive function, and global cognition without evidence of BBB opening or adverse events. The single tested parameter—low‑intensity sonication below the BBB‑opening threshold (~135 kPa, MI 0.27)—was associated with these effects.
Safety-related matter No adverse events were reported; DCE-MRI showed no evidence of BBB opening and pre-procedure blood tests, ECG, and chest X-ray were normal. No adverse events were observed during outpatient follow-up for up to one year, and the authors state the low-intensity tFUS was safely delivered.

Brain Region

Ultrasound Parameters

Focal Characteristics Focal depth: None; Focal length: None; Aperture size: None
Treatment frequency Single

We are open to feedback. If you see a mistake or have a suggestion, please contact us.