Therapeutic ultrasound: The future of epilepsy surgery?
Authors: Bex A, Bex V, Carpentier A, Mathon B
Epilepsy is one of the leading neurological diseases in both adults and children and in spite of advancement in medical treatment, 20 to 30% of patients remain refractory to current medical treatment. Medically intractable epilepsy has a real impact on a patient's quality of life, neurologic morbidity and even mortality. Actual therapy options are an increase in drug dosage, radiosurgery, resective surgery and non-resective neuromodulatory treatments (deep brain stimulation, vagus nerve stimulation). Resective, thermoablative or neuromodulatory surgery in the treatment of epilepsy are invasive procedures, sometimes requiring long stay-in for the patients, risks of permanent neurological deficit, general anesthesia and other potential surgery-related complications such as a hemorrhage or an infection. Radiosurgical approaches can trigger radiation necrosis, brain oedema and transient worsening of epilepsy. With technology-driven developments and pursuit of minimally invasive neurosurgery, transcranial MR-guided focused ultrasound has become a valuable treatment for neurological diseases. In this critical review, we aim to give the reader a better understanding of current advancement for ultrasound in the treatment of epilepsy. By outlining the current understanding gained from both preclinical and clinical studies, this article explores the different mechanisms and potential applications (thermoablation, blood brain barrier disruption for drug delivery, neuromodulation and cortical stimulation) of high and low intensity ultrasound and compares the various possibilities available to patients with intractable epilepsy. Technical limitations of therapeutic ultrasound for epilepsy surgery are also detailed and discussed.
Introduction
Purpose
Thermal ablation
Study Objective
To assess the potential role of therapeutic ultrasound as a future alternative or adjunct in epilepsy surgery.
Disease model
epilepsy
Outcomes and Safety
Summary of Outcomes
The supplied excerpt contains only the paper title and reports no experimental biological or behavioral effects or tested focused ultrasound parameters.
Safety-related matter
No safety-related information or adverse effects are mentioned in the provided text.
Brain Region
Ultrasound Parameters
Focal Characteristics
Focal depth: None; Focal length: None; Aperture size: None
We are open to feedback. If you see a mistake or have a suggestion, please contact us.
← Back to Search