Tissue specific considerations in implementing high intensity focussed ultrasound under magnetic resonance imaging guidance.
Authors: deSouza NM, Gedroyc W, Rivens I, Ter Haar G
High-intensity focused ultrasound can ablate a target permanently, leaving tissues through which it passes thermally unaffected. When delivered under magnetic resonance (MR) imaging guidance, the change in tissue relaxivity on heating is used to monitor the temperatures achieved. Different tissue types in the pre-focal beam path result in energy loss defined by their individual attenuation coefficients. Furthermore, at interfaces with different acoustic impedances the beam will be both reflected and refracted, changing the position of the focus. For complex interfaces this effect is exacerbated. Moreover, blood vessels proximal to the focal region can dissipate heat, altering the expected region of damage. In the target volume, the temperature distribution depends on the thermal conductivity (or diffusivity) of the tissue and its heat capacity. These are different for vascular tissues, water and fat containing tissues and bone. Therefore, documenting the characteristics of the pre-focal and target tissues is critical for effective delivery of HIFU. MR imaging provides excellent anatomic detail and characterization of soft tissue components. It is an ideal modality for real-time planning and monitoring of HIFU ablation, and provides non-invasive temperature maps. Clinical applications involve soft-tissue (abdomino-pelvic applications) or bone (brain applications) pre-focally and at the target (soft-tissue tumors and bone metastases respectively). This article addresses the technical difficulties of delivering HIFU effectively when vascular tissues, densely cellular tissues, fat or bone are traversed pre-focally, and the clinical applications that target these tissues. The strengths and limitations of MR techniques used for monitoring ablation in these tissues are also discussed.
Introduction
Purpose
Thermal ablation
Study Objective
To evaluate how varying pre-focal and target tissue types influence the delivery, temperature monitoring, and efficacy of MR-guided high-intensity focused ultrasound (HIFU).
MRI or image guidance method
Magnetic Resonance (MR) imaging guidance
Outcomes and Safety
Summary of Outcomes
MR-guided high-intensity focused ultrasound (HIFU) can produce permanent target ablation while MR thermometry provides real-time temperature monitoring, but pre-focal tissue composition (attenuation, acoustic impedance interfaces, vascular heat-sink, and differing thermal properties of fat, bone and soft tissues) alters energy deposition, focus position, and lesion distribution. The paper is a technical/clinical review and did not test or report specific successful focused-ultrasound parameter sets.
Safety-related matter
No specific adverse events are reported; however, the paper notes potential safety concerns — beam reflection/refraction at tissue interfaces can shift the focal spot and blood vessels can dissipate heat, potentially altering or causing unintended regions of tissue damage, so characterization of pre-focal tissues is critical.
Brain Region
Ultrasound Parameters
Focal Characteristics
focal depth: None; focal length: None; aperture size: None