Electroencephalographic Response of Brain Stimulation by Shock Waves From Laser Generated Carbon Nanotube Transducer.
Authors: Lee J, Larocco JW, Paeng DG
Neuromodulation is used to treat neurological disorders. Focused ultrasound can deliver acoustic energy to local regions of the brain, including deep brain structures. In addition, it is possible to induce the activation or inhibition of nerves through parameter adjustments of focused ultrasound. Laser-generated focused ultrasound (LGFUS) has demonstrated a potential use in precise therapeutic ultrasound applications owing to the ability to produce high-pressure, broadband frequency of shock waves with a tight focal spot, resulting in confined acoustic exposure of a small area. However, there have been few studies of neurostimulation using shock waves with pulse durations of several nanoseconds. The purpose of this study is to investigate the possibility of neurostimulation by shock waves generated from a focused Carbon Nanotube (fCNT) transducer. We measured electroencephalographic (EEG) signals in three rat brains before and after shock wave stimulation and compared them in the time and frequency domains. In the time domain, the number of peaks of EEG signals was measured significantly higher after shock wave stimulation than before stimulation in all three rats. The three rats showed differences in three frequency bands: theta(4-7 Hz), alpha(8-12), and 1-30 Hz, before and after shock wave stimulation (p < 0.001). These differences in EEG signals after shock wave stimulation of three rats were confirmed mainly because of shock waves. The stimulation of a rat brain was feasible using shock waves generated by the fCNT transducer. This study provides a basis for the applications of shock waves to brain stimulation for precise targeting.
Introduction
Purpose
Transcranial ultrasound stimulation
Study Objective
To investigate the electroencephalographic responses to brain stimulation using shock waves produced by a laser-generated carbon nanotube transducer.
Animal model / Human subject
Rat
Disease model
healthy
Cargo name and characteristics
Nanoparticle
Outcomes and Safety
Summary of Outcomes
Shock waves produced by a laser-generated carbon nanotube transducer induce measurable electroencephalographic changes, demonstrating that this method can evoke brain electrophysiological responses.
Brain Region
Ultrasound Parameters
Ultrasound instrument
Focused Carbon Nanotube (fCNT) transducer
FUS Frequency
4 MHz
FUS Intensity
ISPTA: 8 mW/cm^2, ISPPA: 10.7 kW/cm^2, ISPTP: 68 kW/cm^2
FUS Pressure
9.79 MPa
FUS Mode
pulsed
Pulse duration
NR
Focal Characteristics
(F# =0.7 , focal length =1.4 cm)