Pitt Shield

Low Intensity Focused Ultrasound for Epilepsy- A New Approach to Neuromodulation.

Authors: Bubrick EJ, McDannold NJ, White PJ

Patients with drug-resistant epilepsy (DRE) who are not surgical candidates have unacceptably few treatment options. Benefits of implanted electrostimulatory devices are still largely palliative, and many patients are not eligible to receive them. A new form of neuromodulation, low intensity focused ultrasound (LIFUS), is rapidly emerging, and has many potential intracranial applications. LIFUS can noninvasively target tissue with a spatial distribution of highly focused acoustic energy that ensures a therapeutic effect only at the geometric focus of the transducer. A growing literature over the past several decades supports the safety of LIFUS and its ability to noninvasively modulate neural tissue in animals and humans by positioning the beam over various brain regions to target motor, sensory, and visual cortices as well as frontal eye fields and even hippocampus. Several preclinical studies have demonstrated the ability of LIFUS to suppress seizures in epilepsy animal models without damaging tissue. Resection after sonication to the antero-mesial lobe showed no pathologic changes in epilepsy patients, and this is currently being trialed in serial treatments to the hippocampus in DRE. Low intensity focused ultrasound is a promising, novel, incisionless, and radiation-free alternative form of neuromodulation being investigated for epilepsy. If proven safe and effective, it could be used to target lateral cortex as well as deep structures without causing damage, and is being studied extensively to treat a wide variety of neurologic and psychiatric disorders including epilepsy.

Introduction

Purpose Transcranial ultrasound stimulation
Study Objective To assess the potential of low-intensity focused ultrasound (LIFUS) as a safe, noninvasive neuromodulation therapy for drug-resistant epilepsy.
Disease model drug-resistant epilepsy (DRE)
Targeted brain region(s) Hippocampus

Outcomes and Safety

Summary of Outcomes Low-intensity focused ultrasound (LIFUS) noninvasively modulates neural activity and can suppress seizures in animal models while appearing safe in humans (no pathologic changes after hippocampal sonication); the paper does not report specific ultrasound parameter sets as being tested or successful.
Safety-related matter The paper states that a growing literature supports the safety of low intensity focused ultrasound (LIFUS) in animals and humans, with preclinical seizure models showing seizure suppression without tissue damage and post‑sonication resections in epilepsy patients showing no pathologic changes; no specific adverse effects are reported.

Brain Region

Ultrasound Parameters

Focal Characteristics Focal depth: None; Focal length: None; Aperture size: None
Treatment frequency Multiple

We are open to feedback. If you see a mistake or have a suggestion, please contact us.

← Back to Search