Small volume blood-brain barrier opening in macaques with a 1 MHz ultrasound phased array.
Authors: Manuel TJ, Sigona MK, Phipps MA, Kusunose J, Luo H, Yang PF, Newton AT, Gore JC, Grissom W, Chen LM, Caskey CF
Focused ultrasound blood-brain barrier (BBB) opening is a promising tool for targeted delivery of therapeutic agents into the brain. The volume of opening determines the extent of therapeutic administration and sets a lower bound on the size of targets which can be selectively treated. We tested a custom 1 MHz array transducer optimized for cortical regions in the macaque brain with the goal of achieving small volume openings. We integrated this device into a magnetic resonance image guided focused ultrasound system and demonstrated twelve instances of small volume BBB opening with average opening volumes of 59 ± 37 mm <sup>3</sup> and 184 ± 2 mm <sup>3</sup> in cortical and subcortical targets, respectively. We developed real-time cavitation monitoring using a passive cavitation detector embedded in the array and characterized its performance on a bench-top flow phantom mimicking transcranial BBB opening procedures. We monitored cavitation during <i>in-vivo</i> procedures and compared cavitation metrics against opening volumes and safety outcomes measured with FLAIR and susceptibility weighted MR imaging. Our findings show small BBB opening at cortical targets in macaques and characterize the safe pressure range for 1 MHz BBB opening. Additionally, we used subject-specific simulations to investigate variance in measured opening volumes and found high correlation (R <sup>2</sup> = 0.8577) between simulation predictions and observed measurements. Simulations suggest the threshold for 1 MHz BBB opening was 0.53 MPa. This system enables BBB opening for drug delivery and gene therapy to be targeted to more specific brain regions.
Introduction
Purpose
Drug delivery with BBB opening
Study Objective
To evaluate a custom 1 MHz array transducer integrated with MRI-guided focused ultrasound for producing and monitoring small-volume blood–brain barrier openings in the macaque brain.
Animal model / Human subject
Macaque (non-human primate), strain: not specified, age: not specified, sex: not specified
Disease model
Healthy
MRI or image guidance method
Magnetic resonance image-guided focused ultrasound (MRgFUS)
Targeted brain region(s)
Cortical And Subcortical Regions
Outcomes and Safety
Summary of Outcomes
1 MHz focused ultrasound generated small localized BBBO in macaques, with mean volumes of 59+-37 mm3 in cortical targets and 184+-2 mm3 in subcortical targets; real-time cavitation monitoring was used alongside MRI to characterize safe operating conditions. Subject-specific simulations had strong correlation with measured opening volumes (R2= 0.8577) and identified a 0.53 MPa BBB opening threshold.
Safety-related matter
Safety outcomes were assessed with FLAIR and susceptibility-weighted MR imaging, and the authors report characterization of a safe pressure range for 1 MHz BBB opening; no adverse effects are reported.
Brain Region
Ultrasound Parameters
Ultrasound instrument
Custom 1 MHz array transducer integrated into an MR-guided focused ultrasound system; manufacturer: None; transducer aperture/diameter: None
FUS Frequency
1 MHz
FUS Pressure
0.53 MPa
Focal Characteristics
focal depth: None, focal length: None, aperture size: None
We are open to feedback. If you see a mistake or have a suggestion, please contact us.
← Back to Search