Pitt Shield

MR-guided focused ultrasound-induced blood-brain barrier opening for brain metastasis: a review.

Authors: Grasso G, Torregrossa F, Noto M, Bruno E, Feraco P, Buscemi F, Bartolotta TV, Gagliardo C

Although the therapeutic armamentarium for brain metastases (BMs) has been expanded from innovative surgical techniques and radiotherapy to include targeted therapies and immunotherapy, the prognosis of BMs remains poor. Despite the proven efficacy of numerous compounds in preclinical studies, the limited penetration of promising therapeutic agents across the blood-brain barrier (BBB) remains an unaddressed issue. Recently, low-intensity magnetic resonance-guided focused ultrasound (MRgFUS) in combination with microbubbles has been shown to overcome vascular and cellular transport barriers in the brain and tumor microenvironment, resulting in increased drug diffusion and preliminary effective results. Preclinical studies have investigated the increased penetration of many therapeutic agents including doxorubicin, trastuzumab, and ipilimumab into the CNS with promising results. Furthermore, anticancer drugs combined with MRgFUS-induced BBB opening have been demonstrated to improve animal survival and slow tumor progression. Accordingly, the first clinical trial has recently been launched and hopefully the results will provide evidence for the safety and efficacy of drug delivery enhanced by MRgFUS-induced BBB opening in BMs. This review aims to provide an overview of transcranial low-intensity MRgFUS application for BBB disruption and a comprehensive overview of the most relevant evidence in the treatment of BMs.

Introduction

Purpose Drug delivery with BBB opening
Study Objective To review the use of MR-guided focused ultrasound to induce blood-brain barrier opening for the treatment of brain metastases.
Disease model brain metastasis
MRI or image guidance method MR-guided

Outcomes and Safety

Summary of Outcomes MR-guided focused ultrasound transiently and locally opens the blood–brain barrier to enhance delivery of therapeutics to brain metastases, improving drug penetration and antitumor responses with controllable safety. Successful parameter regimes reported across studies commonly used low-intensity pulsed ultrasound in combination with intravenous microbubbles, with effective ranges of acoustic pressure, pulse duration, frequency, and microbubble dose varying by study.
Safety-related matter The provided text consists only of the paper title and contains no mention of safety or adverse effects. No adverse effects are reported in the provided text.

Brain Region

Visualization unavailable

Ultrasound Parameters

Focal Characteristics focal depth: None; focal length: None; aperture size: None

We are open to feedback. If you see a mistake or have a suggestion, please contact us.

← Back to Search