Equivalent-time-active-cavitation-imaging enables vascular-resolution blood-brain-barrier-opening-therapy planning.
Authors: Desmarais S, Ramos-Palacios G, Porée J, Lee SA, Leconte A, Sadikot AF, Provost J
<i>Objective</i>. Linking cavitation and anatomy was found to be important for predictable outcomes in focused-ultrasound blood-brain-barrier-opening and requires high resolution cavitation mapping. However, cavitation mapping techniques for planning and monitoring of therapeutic procedures either (1) do not leverage the full resolution capabilities of ultrasound imaging or (2) place constraints on the length of the therapeutic pulse. This study aimed to develop a high-resolution technique that could resolve vascular anatomy in the cavitation map.<i>Approach</i>. Herein, we develop BandPass-sampled-equivalent-time-active-cavitation-imaging (BP-ETACI), derived from bandpass sampling and dual-frequency contrast imaging at 12.5 MHz to produce cavitation maps prior and during blood-brain barrier opening with long therapeutic bursts using a 1.5 MHz focused transducer in the brain of C57BL/6 mice.<i>Main results</i>. The BP-ETACI cavitation maps were found to correlate with the vascular anatomy in ultrasound localization microscopy vascular maps and in histological sections. Cavitation maps produced from non-blood-brain-barrier disrupting doses showed the same cavitation-bearing vasculature as maps produced over entire blood-brain-barrier opening procedures, allowing use for (1) monitoring focused-ultrasound blood-brain-barrier-opening (FUS-BBBO), but also for (2) therapy planning and target verification.<i>Significance</i>. BP-ETACI is versatile, created high resolution cavitation maps in the mouse brain and is easily translatable to existing FUS-BBBO experiments. As such, it provides a means to further study cavitation phenomena in FUS-BBBO.
Introduction
Purpose
Drug delivery with BBB opening
Study Objective
To develop and validate equivalent-time active cavitation imaging as a method for planning blood–brain barrier opening therapy with vascular resolution.
Outcomes and Safety
Summary of Outcomes
Equivalent-time active cavitation imaging provides vascular-resolution monitoring that enables planning of focused ultrasound–mediated blood–brain barrier opening, improving spatial targeting and control of cavitation during therapy. The provided text does not report specific focused-ultrasound parameter sets or which parameter variants were tested/successful.
Safety-related matter
The provided text contains no mention of safety, adverse effects, or related findings.
Brain Region
Ultrasound Parameters
FUS Mode
pulsed
Focal Characteristics
Focal depth: None; Focal length: None; Aperture size: None
We are open to feedback. If you see a mistake or have a suggestion, please contact us.
← Back to Search