Ultrasound-Assisted H<sub>2</sub> Transmitter Enables Hydrogen-Gene Therapy to Prevent Anesthesia/Surgery-Induced Cognitive Impairment.
Authors: Zhan R, Fang Y, Lou C, Chen N, Mo X, Jiao B, Liu M, Zhao Y, Xu W, Xu H, Yin H, Zhang Y
Postoperative cognitive dysfunction (POCD) frequently occurs after surgery, resulting in extended hospitalizations, higher healthcare expenses, and potential long-term cognitive impairment. Despite its significant impact, effective preventive and therapeutic strategies for POCD are still lacking. Neuroinflammation plays a crucial role in the pathogenesis of POCD. To address this, a H<sub>2</sub> emitter is developed that employs hydrogen-gene therapy facilitated by ultrasound, allowing for the repair of the neuroinflammatory microenvironment in a spatiotemporally controllable manner to effectively prevent anesthesia/surgery-induced cognitive impairment. Utilizing focused ultrasound, the blood-brain barrier can be opened in a controlled manner, enabling the efficient delivery of hydrogen emitters (HPPS) carrying siRNA to the site of neuroinflammation. On one hand, the hydrogen emitter effectively generates hydrogen to eliminate excess hydroxyl radicals; on the other hand, it utilizes siRNA to target and reduce tau protein phosphorylation. This targeted hydrogen-gene therapy strategy has been demonstrated in both mouse and rat postoperative models to significantly reduce neuroinflammation and improve postoperative spatial memory as well as object recognition. This study introduces a novel and effective strategy for preventing anesthesia/surgery-induced cognitive impairment and offering new insights for the treatment of other neuroinflammatory diseases.
Introduction
Purpose
Drug delivery with BBB opening
Study Objective
To develop and evaluate an ultrasound-assisted hydrogen transmitter that enables hydrogen-gene therapy to prevent anesthesia/surgery-induced cognitive impairment.
Disease model
Anesthesia/surgery-induced cognitive impairment (postoperative cognitive dysfunction)
Cargo name and characteristics
Gene therapy vector (nucleic acid) encoding an H2-producing transgene (gene therapy); therapeutic small molecule: hydrogen gas (H2) produced in situ
Outcomes and Safety
Summary of Outcomes
An ultrasound-assisted H2 transmitter enabling hydrogen-gene therapy prevented anesthesia/surgery-induced cognitive impairment. The provided text does not specify any focused ultrasound parameters or which settings were successful.
Safety-related matter
The provided text contains no mention of safety issues or adverse effects.
Brain Region
Ultrasound Parameters
Focal Characteristics
focal depth: None; focal length: None; aperture size: None
We are open to feedback. If you see a mistake or have a suggestion, please contact us.