Pitt Shield

Ultrasound-Assisted H<sub>2</sub> Transmitter Enables Hydrogen-Gene Therapy to Prevent Anesthesia/Surgery-Induced Cognitive Impairment.

Authors: Zhan R, Fang Y, Lou C, Chen N, Mo X, Jiao B, Liu M, Zhao Y, Xu W, Xu H, Yin H, Zhang Y

Postoperative cognitive dysfunction (POCD) frequently occurs after surgery, resulting in extended hospitalizations, higher healthcare expenses, and potential long-term cognitive impairment. Despite its significant impact, effective preventive and therapeutic strategies for POCD are still lacking. Neuroinflammation plays a crucial role in the pathogenesis of POCD. To address this, a H<sub>2</sub> emitter is developed that employs hydrogen-gene therapy facilitated by ultrasound, allowing for the repair of the neuroinflammatory microenvironment in a spatiotemporally controllable manner to effectively prevent anesthesia/surgery-induced cognitive impairment. Utilizing focused ultrasound, the blood-brain barrier can be opened in a controlled manner, enabling the efficient delivery of hydrogen emitters (HPPS) carrying siRNA to the site of neuroinflammation. On one hand, the hydrogen emitter effectively generates hydrogen to eliminate excess hydroxyl radicals; on the other hand, it utilizes siRNA to target and reduce tau protein phosphorylation. This targeted hydrogen-gene therapy strategy has been demonstrated in both mouse and rat postoperative models to significantly reduce neuroinflammation and improve postoperative spatial memory as well as object recognition. This study introduces a novel and effective strategy for preventing anesthesia/surgery-induced cognitive impairment and offering new insights for the treatment of other neuroinflammatory diseases.

Introduction

Purpose Drug delivery with BBB opening
Study Objective To develop and evaluate an ultrasound-assisted hydrogen transmitter that enables hydrogen-gene therapy to prevent anesthesia/surgery-induced cognitive impairment.
Animal model / Human subject Mice (C57BL/6J, sex: female, age: 12-14 months), Sprague-Dawley rats (age: 10 months)
Disease model postoperative cognitive dysfunction
Targeted brain region(s) Hippocampus
Target coordinates Mice: AP: -2.0 mm, ML: +/- 1.5 mm, DV: -1.5 mm; Rats: AP: -3.0 mm, ML: +/- 2.0 mm, DV: -3.0 mm
Cargo name and characteristics hydrogen emitters (HPPS) with siRNA
Route of administration intravenous

Outcomes and Safety

Summary of Outcomes Delivery hydrogen emitters for gene therapy successfully mitigated neuroinfalmmation.
Safety-related matter The safety of the FUS-BBBO was assessed, showing no microhemorrhages.

Brain Region

Ultrasound Parameters

FUS Frequency 1 MHz
FUS Pressure 0.6 MPa
Pulse duration 10 ms
Duration of a single FUS session 60 s, 30 s
Focal Characteristics diameter: 38 mm

We are open to feedback. If you see a mistake or have a suggestion, please contact us.

← Back to Search