Pitt Shield

Ultrasonic head-mounted device spatiotemporal opening blood-brain barrier enhances the brain permeation of drugs for treatment of radiation-induced brain injury.

Authors: Tang Z, Niu H, Wu Y, Zhang Y, Zhang F, Wang C, Zhang S, Song X, Wang Y, Du L, Jin Y

The field of physical therapy is advancing and using focused ultrasound to deliver drugs into the brain gains growing interest. However, the blood-brain barrier makes it difficult for drugs to enter. Finding safe and efficient physical therapy strategies to complement drug treatments is essential. Here, the rule and molecular mechanisms of spatiotemporal opening blood-brain barrier of ultrasound were explored using a Bluetooth-controlled ultrasonic head-mounted device which was used to enhance the brain permeation of drugs for the treatment of radiation-induced brain injury. The falling-off of tight junction proteins in the blood-brain barrier was the key to spatiotemporally opening under ultrasound. Evans blue and Rhodamine B represented macromolecules and small molecules, respectively, which were intravenously injected into the circulation. Their brain permeation was promoted by brain ultrasound and the smaller molecules required the lower sound intensity that also affected the speed of drug-passing. During the blood-brain barrier restoration after ultrasound, biomarkers like enzymes and growth factors changed, which could be used for selection of dosing window. After the use of the helmet, the blood-brain barrier was restored after 24 h, and the efficacy of water-soluble drugs for the treatment of radiation brain injury was increased. It was suitable for non-invasive external use and enhanced the treating effect when cooperating with drugs. This study provides a research basis for applying ultrasound technology into physio-pharmacotherapy.

Introduction

Purpose Drug delivery with BBB opening
Study Objective To evaluate whether a head-mounted ultrasonic device that spatiotemporally opens the blood-brain barrier can enhance brain drug permeation for treating radiation-induced brain injury.
Disease model radiation-induced brain injury

Outcomes and Safety

Summary of Outcomes A head-mounted ultrasonic device produced spatiotemporal opening of the blood–brain barrier, enhancing brain permeation of therapeutic drugs and improving treatment outcomes for radiation-induced brain injury. No specific focused ultrasound parameter details were provided in the supplied text.
Safety-related matter No safety issues or adverse effects are mentioned in the provided text.

Brain Region

Visualization unavailable

Ultrasound Parameters

Focal Characteristics Focal depth: None; Focal length: None; Aperture size: None

We are open to feedback. If you see a mistake or have a suggestion, please contact us.

← Back to Search