An advanced focused ultrasound protocol improves the blood-brain barrier permeability and doxorubicin delivery into the rat brain.
Authors: Jung B, Huh H, Lee EH, Han M, Park J
Despite the recent development of a focused ultrasound (FUS) technique for disrupting the blood-brain barrier (BBB) and enabling the delivery of drugs into the targeted brain region, different sonication protocols have not been fully explored. In this study, we suggest a simple and cost-effective protocol that improves the BBB permeability and drug delivery without damaging the tissue. In this protocol, called "FUS+BBBD protocol", an additional FUS stimulation without microbubbles ("FUS protocol"; 0.5, 1.0, or 2.0MPa acoustic pressure, 10ms tone burst, 1Hz pulse repetition frequency, 120s total duration) is applied prior to the conventional BBB disruption with microbubbles ("BBBD protocol"; 0.6∼0.72MPa acoustic pressure, 10ms tone burst, 1Hz pulse repetition frequency, 120s total duration). With the "FUS+BBBD protocol", the magnetic resonance signal intensity and doxorubicin delivery at the targeted brain region were increased by 1.59 and 1.75 times at an FUS intensity of 1.0MPa, respectively, compared to the conventional BBBD. Other conditions also increase the drug delivery, but the increase was smaller than that at 1.0MPa (1.15 times for 0.5MPa and 1.60 times for 2.0MPa). The H&E histopathological analysis of the sonicated brain region using the proposed "FUS+BBBD protocol" showed no significant brain tissue damage at a FUS intensity of 0.5 and 1.0MPa. However, region cavities due to the damage were observed after an FUS intensity of 2.0MPa. These results suggest that the 1.0MPa "FUS+BBBD protocol" increases the BBB permeability and enhances the drug delivery efficiency without noticeable brain tissue damage, compared with the conventional BBBD. Although further studies are needed to determine the underlying mechanism of this effect, drugs that have been reported to be effective in the treatment of brain disease but had limited use due to severe systemic side effects will benefit from the enhanced drug delivery of "FUS+BBBD protocol". Furthermore, the suggested protocol may facilitate the development of new strategies in clinical trials to treat brain disorders with improved drug delivery and safety.
Introduction
Purpose
Drug delivery with BBB opening
Study Objective
To determine whether an advanced focused ultrasound protocol can enhance blood-brain barrier permeability and increase delivery of doxorubicin to the rat brain.
Animal model / Human subject
Rattus norvegicus, not reported, not reported, not reported
Disease model
healthy
Targeted brain region(s)
Brain
Cargo name and characteristics
doxorubicin
Route of administration
intravenous
Outcomes and Safety
Summary of Outcomes
An advanced focused ultrasound protocol increased blood–brain barrier permeability and enhanced doxorubicin delivery into the rat brain (specific ultrasound parameters not specified).
Duration of biological effect
not reported
Safety-related matter
not reported
Brain Region
Ultrasound Parameters
Ultrasound instrument
focused ultrasound transducer
FUS Frequency
690 kHz
FUS Intensity
not reported
FUS Pressure
not reported
FUS Mode
not reported
Pulse duration
10 ms
Duration of a single FUS session
120 s
Treatment frequency
single session