Potential of magnetic resonance-guided focused ultrasound for intracranial hemorrhage: an in vivo feasibility study.
Authors: Harnof S, Zibly Z, Hananel A, Monteith S, Grinfeld J, Schiff G, Kulbatski I, Kassell N
Because of the paucity of effective treatments for intracranial hemorrhage (ICH), the mortality rate remains at 40%-60%. A novel application of magnetic resonance-guided focused ultrasound (MRgFUS) for ICH may offer an alternative noninvasive treatment through the precise delivery of FUS under real-time MR imaging (MRI) guidance. The purpose of the present study was to optimize the parameters for rapid, effective, and safe trans-skull large clot liquefaction using in vivo porcine and ex vivo human skull models to provide a clinically relevant proof of concept. The transcranial effectiveness of MRgFUS was tested ex vivo by introducing a porcine blood clot into a human skull, without introducing tissue plasminogen activator (tPA). We used an experimental human head device to deliver pulsed FUS sonications at an acoustic power of 600-900 W for 5-10 seconds. A 3-mL clot was also introduced in a porcine brain and sonicated in vivo with one 5-second pulse of 700 W through a bone window or with 3000 W when treated through an ex vivo human skull. Treatment targeting was guided by MRI, and the tissue temperature was monitored online. Liquefied volumes were measured as hyperintense regions on T2-weighted MR images. In both in vivo porcine blood clot through a craniectomy model and the porcine clot in an ex vivo human skull model targeted clot liquefaction was achieved, with only marginal increase in temperature in the surrounding tissue. Our results demonstrate the feasibility of fast, efficient, and safe thrombolysis in an in vivo porcine model of ICH and in 2 ex vivo models using a human skull, without introducing tPA. Future studies will further optimize parameters and assess the nature of sonication-mediated versus natural clot lysis, the risk of rebleeding, the potential effect on the adjacent parenchyma, and the chemical and toxicity profiles of resulting lysate particles.
Introduction
Purpose
Other
Study Objective
To assess the feasibility of using magnetic resonance-guided focused ultrasound to treat intracranial hemorrhage in vivo.
Animal model / Human subject
pig, not specified, not specified, not specified
Disease model
intracranial hemorrhage
Targeted brain region(s)
Intracranial Hemorrhage Site
Outcomes and Safety
Summary of Outcomes
MR-guided focused ultrasound was evaluated for treating intracranial hemorrhage in vivo.
Duration of biological effect
not reported
Safety-related matter
Safety not reported.
Brain Region
Ultrasound Parameters
Ultrasound instrument
not reported
FUS Frequency
not reported
FUS Intensity
not reported
FUS Pressure
not reported
FUS Mode
pulsed
Pulse duration
not reported
Duration of a single FUS session
5 s
Treatment frequency
single
We are open to feedback. If you see a mistake or have a suggestion, please contact us.
← Back to Search