Reorganization of gap junctions after focused ultrasound blood-brain barrier opening in the rat brain.

Authors: Alonso A, Reinz E, Jenne JW, Fatar M, Schmidt-Glenewinkel H, Hennerici MG, Meairs S

Ultrasound-induced opening of the blood-brain barrier (BBB) is an emerging technique for targeted drug delivery to the central nervous system. Gap junctions allow transfer of information between adjacent cells and are responsible for tissue homeostasis. We examined the effect of ultrasound-induced BBB opening on the structure of gap junctions in cortical neurons, expressing Connexin 36, and astrocytes, expressing Connexin 43, after focused 1-MHz ultrasound exposure at 1.25 MPa of one hemisphere together with intravenous microbubble (Optison, Oslo, Norway) application. Quantification of immunofluorescence signals revealed that, compared with non-insonicated hemispheres, small-sized Connexin 43 and 36 gap-junctional plaques were markedly reduced in areas with BBB breakdown after 3 to 6 hours (34.02+/-6.04% versus 66.49+/-2.16%, P=0.02 for Connexin 43; 33.80+/-1.24% versus 36.77+/-3.43%, P=0.07 for Connexin 36). Complementing this finding, we found significant increases in large-sized gap-junctional plaques (5.76+/-0.96% versus 1.02+/-0.84%, P=0.05 for Connexin 43; 5.62+/-0.22% versus 4.65+/-0.80%, P=0.02 for Connexin 36). This effect was reversible at 24 hours after ultrasound exposure. Western blot analyses did not show any change in the total connexin amount. These results indicate that ultrasound-induced BBB opening leads to a reorganization of gap-junctional plaques in both neurons and astrocytes. The plaque-size increase may be a cellular response to imbalances in extracellular homeostasis after BBB leakage.

Introduction

Purpose Drug delivery with BBB opening
Study Objective To determine how ultrasound-induced opening of the blood–brain barrier affects the structure and size distribution of Connexin36-expressing neuronal and Connexin43-expressing astrocytic gap junctions.
Animal model / Human subject rat, Sprague-Dawley, not reported, male
Disease model healthy
Targeted brain region(s) Cortex

Outcomes and Safety

Summary of Outcomes FUS-induced BBB opening transiently reorganized cortical gap-junctional plaques at 3–6 h.
Duration of biological effect 3-6h
Safety-related matter No adverse effects reported.

Brain Region

Ultrasound Parameters

Ultrasound instrument not reported
FUS Frequency 1 MHz
FUS Intensity not reported
FUS Pressure 1.25 MPa
FUS Mode not reported
Pulse duration 10 ms
Duration of a single FUS session 60 s
Treatment frequency single session
Mechanical index 1.25