[An experimental study of stereotaxic destruction on the cat brain by intense focused ultrasound. The improvement of the apparatus for experiment].

Authors: Ishii M

No abstract available

Introduction

Purpose Thermal ablation
Study Objective To experimentally evaluate stereotaxic destruction of the cat brain using intense focused ultrasound and to improve the experimental apparatus.
Animal model / Human subject cat, domestic, adult, not reported
Disease model healthy
Targeted brain region(s) Thalamus

Outcomes and Safety

Summary of Outcomes A stereotaxic intense FUS system produced highly localized destructive lesions in the cat brain, demonstrating precise spatial control for functional neurosurgery
Duration of biological effect not reported
Safety-related matter The system enabled precise lesioning with minimal damage to intervening tissues; however, precise alignment and cooling were required to avoid non-target thermal injury.

Brain Region

Ultrasound Parameters

Ultrasound instrument multibeam focused ultrasound system with stereotaxic frame
FUS Frequency 1.0 MHz
FUS Intensity not reported
FUS Pressure not reported
FUS Mode not reported
Pulse duration not reported
Duration of a single FUS session 0.5–2.0 s